Check the hydraulic components for leaks or damage
WHAT YOU NEED
Standard Personal Protective Equipment
CAUTIONSHARP BLADE: Keep clear of the saw blade while working inside the saw chamber.
- Using the Manual Mode window, move the Y-axis to the middle position and the Z-axis to the lowest position.
- Press the E‑stop button on the operator console.
- Open the saw chamber door.
-
Inspect the following for any signs of leaks or damage:
- the rotary coupling in the saw chamber
- all the connections into the rotary coupling
- the blade motor in the saw chamber
- all the connections into the blade motor
- the hydraulic hoses from the hydraulic power pack to the saw
- all the connections and fittings on the hydraulic power pack
- all the seals and caps on the hydraulic power pack